Barracuda confirmed attacks on two flaws in its Email Security Gateway that, chained together, give full control of the appliance with no username or password. Which devices are affected, which patch to apply and what to check.
On November 2, 2026, Barracuda Networks released patches for two flaws that, chained together, let an attacker with no username or password gain root access (full control of the device) on its Email Security Gateway, the appliance that screens a company's email before it reaches the mailboxes. On November 5, the security firm watchTowr published a detailed technical analysis of how they combine, so other attackers now have the path laid out.
What the flaws are
- CVE-2026-116606 (9.3 out of 10): an authorization flaw lets anyone, without signing in, restore a crafted configuration backup and change the appliance's global settings. It affects Email Security Gateway versions earlier than 9.4.0.030.
- CVE-2026-111560 (8.6 out of 10): a command injection (the attacker slips system commands into a text field) in the time zone setting, which later runs as root. It normally requires an administrator account, but the first flaw removes that requirement.
According to watchTowr, when a password change attempt fails, the appliance does not stop the request and leaves the backup restore function open. Those backups carry a checksum, but the key used to compute it is hardcoded, so an attacker can forge a backup the appliance accepts. The second flaw also affects other Barracuda products that share the same code: Web Application Firewall, Load Balancer ADC, Message Archiver, Web Security Gateway and WAF Control Center.
Who is exposed
To attack the email gateway, an attacker has to reach its administration interface. On November 5, Barracuda corrected its advisory to clarify that the first flaw requires no authentication, only that this interface be reachable by the attacker. That is why appliances with their administration exposed to the internet face the greatest risk. As of November 8, neither flaw is in the exploited vulnerabilities catalog of the US Cybersecurity and Infrastructure Security Agency (CISA), and its analysis in the CVE records shows no exploitation. watchTowr released a tool to check whether an appliance is vulnerable.
What to do
- Log in to the Email Security Gateway console and confirm it runs firmware 9.4.0.030 or later, or that it received patch BNSF-40425 (for 9.4.017 and later) or BNSF-40430 (for earlier versions).
- If you turned off automatic updates, turn them back on, as Barracuda recommends, and apply the patch manually if it has not arrived. If the firmware is far behind, you may need several updates in a row.
- Restrict the administration interface to the internal network or trusted IP addresses; do not leave it open to the internet.
- If you use other Barracuda products on the list, also apply the patch the advisory gives for each one.
- If the administration interface was exposed before patching, review the appliance's configuration changes and accounts, and change their passwords.
November 10 update: Barracuda confirms attacks
On November 9 at 9:00 p.m. Eastern Time (the same as Colombia time in November), Barracuda updated its advisory to report that it has seen these flaws exploited at a small number of organizations. It gave no further details about the attacks. As of this review, CISA has not yet added them to its catalog. If your email gateway does not have firmware 9.4.0.030 or patch BNSF-40425 or BNSF-40430, apply them today. If its administration interface was open to the internet, follow step 5 even if you have already patched.
November 12 update: CISA adds them to its catalog
On November 10, CISA added CVE-2026-116606 and CVE-2026-111560 to its catalog of exploited vulnerabilities, so the agency now also treats the attacks as confirmed; in the CVE records, its assessment now marks exploitation as active. It gave US federal agencies only three days to fix them, until November 13, while the other flaws it added that day got two weeks. Barracuda has not changed its advisory again since November 9. If your email gateway still lacks firmware 9.4.0.030 or the patches, apply them today.
How we help you
With management of your security and email appliances we check versions and patches, and with network design with isolated administration we take management consoles off the internet. Ask us to review your email gateway.
Sources
- Barracuda: advisory on CVE-2026-116606 and CVE-2026-111560 (November 2, 2026, updated November 5 and 9)
- watchTowr: technical analysis of the attack chain (November 5, 2026)
- CVE Program: CVE-2026-116606 record (November 2, 2026)
- CVE Program: CVE-2026-111560 record (November 2, 2026)
- CISA: CVE-2026-116606 and CVE-2026-111560 in the Known Exploited Vulnerabilities catalog (November 10, 2026)
Source: Barracuda Networks